ALLTEMP Fan Blower Controls - 24-ICM2807
![]() Click to enlarge |
|
Ambient Temperature
- Operating: -40°F to 176°F
- Humidity: 5% to 95% R.H. (non-condensing) @ +55°F
Voltage Range: Line (98 to 132 VAC) @ 60Hz
Ignitor: 5A @ 120 VAC
Cool Blower: 10 HP, 120 VAC
Low Heat: 5A, 1/2 HP, 120 VAC
High Heat: 10A, 1 HP, 120 VAC
Inducer Motor: 4A, FLA-8.0 LRA @ 120 VAC
Gas Valve: 1.5A @ 30 VAC
EAC: 1A@120 VAC
Humidifier: 0.5A & 24 VAC
Direct OEM Replacement Parts
Controls gas valve, ignitor, blower motor, inducer, humidifier and air cleaner
Microprocessor-based precision
Designed for 100% gas shutoff in case of ignition failure
Twinning compatible with another ICM2807 control
Reverse polarity protection
Secondary brownout voltage protection
Compatible with 24 VAC standard thermostat
Continuous Blower Speed Jumper
Limit Switch Lockout Time
Limit Switch Lockout After Power Interruption
Self-Diagnostics
Provides diagnostic