- Voltage Range: Line (98-132 VAC) @ 60Hz
- Cool Blower: 30A, 2 HP, 240 VAC
- Heat: 20A, 240 VAC
- Inducer Motor: 4A FLA, 8A LRA @ 120 VAC
- Ignitor: 10A FLA @ 120 VAC
- Humidifier: 5 amps @ 120 VAC
- Electric Air Cleaner: 5 amps @ 120 VAC
- Trial for Ignition: 7 seconds
- Pre-purge Time: 15 seconds
- Ignitor Warm Up Time: 7 seconds
- Post-Purge Time: 15 seconds
- Total Trials for Ignition: 3 (auto rest after 1 hour)
- Heat Blower On: 30 seconds
- Heat Blower Off: Selectable 90/120/150/180 seconds
- Fan (Heat) On/Off Delay: 1 second
- Cool On: 5 seconds
- Cool Off: 45 seconds
-
Direct OEM Replacement Parts
Controls the gas valve, inducer draft motor, circulating blower and hot surface ignitor
Monitors system pressure and limit switches
Microprocessor based precision
Twinning compatible with another ICM286 Control Board
Diagnostic LEDs aid in testing and troubleshooting
-
Stock Code ALLTEMP_24-ICM286 Brand ALLTEMP Family Direct OEM Replacement Parts Part No 24-ICM286 Cross Refefence Replaces
• Goodman: PCBBF112S, B18099-26S, 0130F00005S