ALLTEMP Fan Blower Controls - 24-ICM291
![]() Click to enlarge |
|
Control Voltage: 24 VAC (18-30 VAC), 60Hz
Line Voltage: 208/230 VAC, 60Hz
Power Consumption: 03A plus gas valve current @ 24 VAC
Operating Temperature: -40°C(-40°F) to 75°C(176°F)
Timing:
- Pre-purge: 45 seconds
- Trial for Ignition: 5+2 seconds
- Retry Period: every 20 seconds for 15 minutes
- Lockout: manual reset
- Post-purge: 45 seconds
Inputs:
- Power: RT and C
- Thermostat Interface: R, W and G
- Safety Switches: RS, LS and CS
- Combustion Motor Hall Effect Sensor
- Flame Sensing
Outputs:
- Spark
- Gas Valve: GV
- Combustion Motor: BM
- Indoor Fan Motor: IFO
LED Indicators:
- Red LED: Steady ON - Normal operation Flashing - Fault codes
Direct OEM Replacement Parts
Direct Spark Ignition (DSI) control board
Microprocessor-based
Controls combustion, blower and indoor motor; spark ignitor and the gas valve
Monitors timing, trial for ignition and lockout
100% lockout safety feature
Compatible with LP or natural gas
Status LED for fault codes to aid in troubleshooting
tock Code | ALLTEMP_24-ICM291 |
---|---|
Brand | ALLTEMP |
Family | Direct OEM Replacement Parts |
Part No | 24-ICM291 |
Cross Refefence |
Replaces • Carrier: LH-33WP003/3A |
Your Review: Note: HTML is not translated!
Rating: Bad Good