ALLTEMP Fan Blower Controls - 24-ICM292
![]() Click to enlarge |
|
Control Voltage: 24 VAC (18-30 VAC), 60Hz
Line Voltage: 115/23 VAC, 60Hz
Power Consumption: 03A plus gas valve curreny @ 24 VAC
Operating Temperature: -40°C(-40°F) to 75°C(176°F)
Timing:
- Pre-purge: 20 seconds
- Trial for Ignition: 6.5 seconds
- Number of Trials: 4 (2+2, 3 minutes apart)
- Lockout: 1 Hour
- Post-purge: dip switch selectable 90, 120, 160, 180 seconds apart
Inputs:
- Power: SEC and COM
- Thermostat Interface: R, W, Y and G
- Safety Switches: Limit and Vent
- Combustion Motor Hall Effect Sensor
- Flame Sensing
Outputs:
- Spark
- Gas Valve: GV
- Induced Draft Motor
- Multi speed indoor blower motor
- Humidifier
LED Indicators:
- PWR(green): Steady ON - power to the board
- OK(green): Steady ON - no fault
- Flashing - fault code
- Flame(yellow): Steady On - flame sensed, flashing two times -flame out of sequence
-
Direct OEM Replacement Parts
Direct Spark Ignition (DSI) control board
Microprocessor-based
Controls Induced Draft and indoor blower motors; humidifier output, spark ignitor and gas valve
Monitors timing, trial for ignition and lockout
100% lockout safety feature
Compatible with LP or natural gas
Status LED for fault codes to aid in troubleshooting
-
Stock Code ALLTEMP_24-ICM292 Brand ALLTEMP Family Direct OEM Replacement Parts Part No 24-ICM292 Cross Refefence Replaces
• Rheem: 62-24140-04