Bodine B94CGU - Emergency Backup Ballast - 90 Min. - Operates (1) 18-42W 4-pin CFL Lamp - Universal Voltage 120-277 Volt
![]() Click to enlarge |
|
The B94CGU can be used with one 18 - 42 W (4-pin) twin, quad or triple twin-tube compact. It is also compatible with most one-, two-, three- and four-lamp electronic, standard, energy-saving and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The B94CGU is suitable for indoor and damp locations.
When AC power fails, the B94CGU immediately switches to the emergency mode, operating one lamp at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast automatically returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.
APPLICATION
The B94CGU emergency ballast works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into emergency lighting. The emergency ballast consists of a high-temperature nickel-cadmium battery, charger and electronic circuitry in one compact case. The B94CGU can be used with one 18 - 42 W (4-pin) twin, quad or triple twin-tube compact. It is also compatible with most one-, two-, three- and four-lamp electronic, standard, energy-saving and dimming AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The B94CGU is suitable for indoor and damp locations. It is not suitable for air handling heated air outlets or wet or hazardous locations. For information about specific lamp and ballast compatibility, please call the factory
OPERATION
When AC power fails, the B94CGU immediately switches to the emergency mode, operating one lamp at a reduced lumen output for a minimum of 90 minutes. When AC power is restored, the emergency ballast automatically returns to the charging mode and, using a patented circuit, delays AC ballast operation for approximately three seconds to prevent false tripping of the AC ballast end-of-lamp-life shutdown circuits.
INSTALLATION
The B94CGU does not affect normal fixture operation and may be used with either a switched or unswitched fixture. If a switched fixture is used, an unswitched hot must be connected to the emergency ballast. The emergency ballast must be fed from the same branch circuit as the AC ballast. The B94CGU may be installed on top of or remote from the fixture. The emergency ballast may be remotely installed up to half the distance the AC ballast manufacturer recommends remoting the AC ballast from the lamp or up to 10 feet, whichever is less. Installation is not recommended with fixtures where the ambient temperature may fall below 0°C. For simple visual inspection of the charging indicator light and easy operational testing, the test/ monitor plate can be installed near the fixture wall switch. It may also be installed in the ceiling near the fixture to ensure an unobtrusive installation.
EMERGENCY ILLUMINATION
Depending on the wattage and type of lamp selected, the B94CGU produces 300 to 750 lumens initial emergency light output (see Table 1). During emergency operation, one lamp is illuminated, even if installed with a multi-lamp AC ballast.
B94CGU
UL, cUL Certified Emergency Lighting Equipment
Replaces B94CG or B94G
Universal input voltage;
One-lamp emergency illumination for
4-pin fluorescent lamps (without integral starter);
Suitable for low mercury lamps
Product Summary
-
UL Listed for US and CanadaFactory or Field Installation
(Indoor and Damp) -
Illumination Time90 Minutes
-
Initial Light Output300 - 750 Lumens
-
Full Warranty2 Years (NOT pro-rata)
-
Universal Input Voltage120 Through 277 VAC, 50 or 60 Hz
-
AC Input Current50 mA
-
AC Input Power Rating4.0 Watts
-
Test SwitchSingle Pole
-
BatteryHigh-Temperature, Maintenance-Free
Nickel-Cadmium Battery
7- to 10-Year Life Expectancy -
Battery Charging Current300 mA
-
Recharge Time24 Hour
-
Charging Indicator LightLED
-
Temperature Rating (Ambient)0°C to + 50°C (32°F to 122°F)
-
Dimensions9.4" x 2.4" x 1.5"
(238 mm x 60 mm x 38 mm)
Mounting Center 8.9" (226 mm) -
Weight3 lbs. (1.4 kg)
Stock Code Bodine_B94CGU Brand Philips Family Flourescent Emergency Ballast, 4-pin Compact Lamps w/o Integral Starter Part No B94CGU Length (in) 9.4" (238mm) Width (in) 2.4" (60mm) Height (in) 1.5" (38mm) Voltage (V) 120-277V, 50/60Hz (120 Through 277VAC) Input Current 50mA Wattage (w) 4.0 Watts Bulb Type Fluorescent Lamps Switch Type: Test Switch: Single Pole Lumens (Initial) 750 Lumens Battery Back Up Yes Battery Type: High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Recharge Time: 24 Hrs Max. Charge Current 300mA Operates one 18 - 42 W (4-pin) twin, quad or triple twin-tube compact fluorescent lamp Start Temp. (Min) 0°C (32°F) Start Temp. (Max) 50°C (122°F) Weight (lb.) 3 lbs UL Listed UL, cUL and Code Compliance Case Quantity 1 Warranty 2 Years (NOT pro-rata) Cross Refefence Replaces model B94G or B94CG