ALLTEMP Gas Ignition - 24-ICM283
Click to enlarge |
|
Input Voltage:120 & 24 VAC, 60Hz
- HSI: 120V, 5A max
- Valve: 24V, 2A max
- Total: 24V Load = 0.4 + valve load
Pre-purge time: 32 seconds
Trial time: 4 or 7 seconds (switch selectable)
Ignition trials to lockout: 1 or 3 (switch selectable)
Flame sense: single rod or dual rod
Gas type: Natural or LP
Gas Ignition Controls
Hot Surface Ignition (HSI) Module
Single/Dual rod sensing capabilities
For gas fired furnaces, boilers and other heating appliances
Switch selectable lockout times
Works with both Natural & LP gas systems
Diagnostic LED to aid in troubleshooting
Stock Code | ALLTEMP_24-ICM283 |
---|---|
Brand | ALLTEMP |
Family | Gas Ignition Controls |
Part No | 24-ICM283 |
Cross Refefence |
• Honeywell: S8910U-1000 • Robertshaw: H5780 • White Rodgers: 50E47, 50F47 |
Your Review: Note: HTML is not translated!
Rating: Bad Good
Enter the code in the box below: