Brands
 
Compare

No items to compare

Bodine 197517 B33 - Parallel Emergency Ballast - 90 Min. - Operates (2) or (3) 32W 4Ft T8 Fluoresent Lamps - 120/277V

Bodine 197517 B33 - Parallel Emergency Ballast - 90 Min. - Operates (2) or (3) 32W 4Ft T8 Fluoresent Lamps - 120/277V
Click to enlarge
Price Per Item: $557.00
Availability: DISCONTINUED
Model: Bodine_B33
Manufacturer: Philips
Average Rating: Not Rated

Qty: Add to Wish List
(This product has a minimum quantity of 1000)

The B33 can be used with two or three 32 W (4’) T8 fluorescent lamps without integral starters. It is compatible ONLY with instant start, parallel two-, three- or four-lamp electronic or standard AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The B33 is suitable for indoor and damp locations. When AC power fails, the B33 immediately switches to the emergency mode, operating either two or three lamps for a minimum of 90 minutes. When AC power is restored, the B33 automatically returns to the charging mode.

APPLICATION

The B33 emergency ballast works in conjunction with an INSTANT START, PARALLEL AC ballast to convert new or existing fluorescent fixtures into emergency lighting. The emergency balast consists of a nickel-cadmium battery, charger and electronic circuitry. The B33 can be used with two or three 32 W (4’) T8 fluorescent lamps without integral starters. It is compatible ONLY with instant start, parallel two-, three- or four-lamp electronic or standard AC ballasts. If used in an emergency-only fixture, no AC ballast is necessary. The B33 is suitable for indoor and damp locations. It is not suitable for air handling heated air outlets or wet or hazardous locations. For information about specific lamp and ballast compatibility, please call the factory. Recommended applications include: hospital surgical suites, areas along the path of egress with high ceiling heights and health care, educational, commercial and institutional facilities needing higher levels of emergency illumination.

OPERATION

When AC power fails, the B33 immediately switches to the emergency mode, operating either two or three lamps for a minimum of 90 minutes. When AC power is restored, the B33 automatically returns to the charging mode.

INSTALLATION

The B33 does not affect normal fixture operation and may be used with either a switched or unswitched fixture. If a switched fixture is used, an unswitched hot lead must be connected to the emergency ballast. The emergency ballast must be fed from the same branch circuit as the AC ballast. The B33 may be installed on top of or remote from the fixture. The emergency ballast may be remotely installed up to half the distance the AC ballast manufacturer recommends remoting the AC ballast from the lamp or up to 50 feet, whichever is less. Installation is not recommended with fixtures where the ambient temperature may fall below +5°C. A charging indicator light and single-pole test switch are provided. Upon request, a single-pole test switch/ monitor plate is provided for remote installation of the test switch and charging indicator. (fits single-gang box)

EMERGENCY ILLUMINATION

The B33 has been optimized for three-lamp operation. The B33 produces 3250 to 3400 lumens initial emergency light output with three 32 W (4’) T8 lamps. Total light output is evenly divided among the lamps for better distribution of emergency illumination.


B33

UL and CSA Certified Emergency Lighting Equipment


Specification-grade, three-lamp parallel emergency illumination; 3400 lumens with three 32 W (4') T8 lamps 

Product Summary

 

  • UL Listed
    Factory or Field Installation
  • Illumination Time
    90 Minutes
  • Initial Light Output
    2700 - 3400 Lumens
  • Full Warranty
    5 Years (NOT pro-rata)
  • Voltage
    120/277 VAC, 60 Hz
  • AC Input Current
    280 mA
  • AC Input Power Rating
    8.0 Watts
  • Test Switch
    Single Pole
  • Battery
    High-Temperature, Maintenance-Free
    Nickel-Cadmium Battery
    7- to 10-Year Life Expectancy
  • Battery Charging Current
    280 mA
  • Recharge Time
    24 Hour
  • Charging Indicator Light
    LED
  • Temperature Rating (Ambient)
    +5°C to +50°C (41°F to 122°F)
  • Dimensions
    16.3" x 5.5" x 1.7"
    (414 mm x 138 mm x 44 mm)
    2' (610 mm) Flexible Conduit
    Mounting Center 15.7" (400 mm)
  • Weight
    8.7 lbs. (3.9 kg)
    Stock Code Bodine_B33
    Brand Philips
    Family CSA Certified Emergency Lighting Equipment
    Part No 197517
    Length (in) 16.3" (414mm)
    Width (in) 5.5" (138mm)
    Height (in) 1.7" (44mm)
    Voltage (V) 120/277V, 60Hz
    Input Current 280mA
    Wattage (w) 8.0 Watts
    Bulb Type Fluorescent Lamps
    Switch Type: Test Switch: Single Pole
    Lumens (Initial) 3400 Lumens
    Battery Back Up Yes
    Battery Type: High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy
    Recharge Time: 24 Hrs
    Max. Charge Current 280mA
    Operates The B33 can be used with two or three 32 W (4’) T8 fluorescent lamps without integral starters. It is compatible ONLY with instant start, parallel two-, three- or four-lamp electronic or standard AC ballasts.
    Start Temp. (Min) 5°C (41°F)
    Start Temp. (Max) 50°C (122°F)
    Weight (lb.) 8.7 lbs
    UL Listed UL, CSA and Code Compliance
    Case Quantity 1
    Warranty 5 Years (NOT pro-rata)
    Notes It is compatible ONLY with instant start, parallel two-, three- or four-lamp electronic or standard AC ballasts
Write Review
Your Name:


Your Review: Note: HTML is not translated!

Rating: Bad            Good

Enter the code in the box below:

There are no additional images for this product.